Description:
EMC laboratories EVPÚ a.s. belong to the top workplaces for EMC measurement in Europe, in particular the Semianechoid chamber of dimensions (L x W x H): 20.5 m x 12.4 m x 7.80 m equipped with top measuring equipment and trained personnel with long-term experience.
- we provide equipment tests to meet the requirements of Directive 2014/30/EU of the European Parliament and of the Council on the harmonization of legislation of member states relating to electromagnetic compatibility (EMC)
- we provide advice and technical cooperation in the testing and development of components and technical units
Measurements:
- measurement of the magnetic and electric component of the electromagnetic field;
- measurement of the level of interfering clamp voltage;
- measurement of radiated power;
- measurement of the level of the electric component of the electromagnetic field;
- measurement of the level of the magnetic component of the electromagnetic field;
- measurement of low-frequency currents;
- measurement of voltage amplitude changes in the distribution network;
Resilience detection:
- detection of resistance to electrostatic discharge
- detection of immunity to interfering electromagnetic fields;
- detection of resistance to electrical impulse bursts (burst test);
- testing for resistance to voltage surges;
- detection of resistance to induced High frequency currents;
- detection of resistance to magnetic fields (nf, pulsed, damped oscillating);
- detection of resistance to oscillatory waves, harmonic and interharmonic. voltage in the distribution network;
Technical equipment:
Measurements and tests shall be carried out:
- Semianechoic chamber, with dimensions (L x W x H): 20.5 m x 12.4 m x 7.80 m;
- Anechoic chamber, with dimensions (L x W x H): 7,30 m x 3,40 m x 3,60 m;
Main instrumentation:
- Rohde & Schwarz ESW 26, receiver 1Hz – 26,5 GHz;
- Rohde & Schwarz SAM 100, amplifier 2GHz – 20GHz, 20W;
- Antenna SA-570, 200 MHz – 1 GHz, „Double ridge horn “, aperture 69,0 cm x 94,5 cm;
- Antenna SA-571, 1 GHz – 18 GHz, „Double ridge horn “, aperture 24,2 cm x 13,6 cm;
- Antenna ROD RA-01 HV 9kHz -30MHz;
- Antenna Biconical HUF-Z2 20MHz- 200 MHz;
Test parameters:
- Emission tests: frequency range: 9 kHz – 26 GHz
- Emission tests under voltage: Frequency range: 9 kHz – 30 MHz
- RF electromagnetic field resistance tests: Frequency range: 26 MHz – 18 GHz
- Electrostatic discharge resistance test: Air: up to 15 kV; Contact: up to 8 kV
- Test for resistance to interference induced by high-frequency fields, propagated by power lines: Frequency range: 150 kHz – 230 MHz
- Shock impulse resistance test: up to 4 kV
- Test for resistance to fast electrical transients/pulse groups: up to 4 kV
Img. 1 – Measurement in the Semianechoid chamber